The LW36-72.5 porcelain post-type high-voltage AC SF6 circuit breaker is equipped with a CT20 spring operating mechanism. It adopts the self-energy arc extinction principle and features a single-break structure. The three poles of each circuit breaker are mounted on a single frame and are mechanically interconnected through a drive mechanism. The electrical control allows for both remote and local operation.
Parameter Name Unit LW36-72.5 LW25-126/145 LW25-252 LW15B-252
LW15-252Rated voltage kV 66 126 / 145 252 252 Rated frequency Hz 50 50 50 50 Rated current A 1250, 3150, 4000 2000, 3150 4000 3150, 4000 Rated breaking current kA 25, 31.5 40 / 31.5 40 50 Rated closing current (peak) kA 80 100 / 80 100 125 Rated short-time withstand current (4s) kA 31.5 40 / 31.5 40 50 Rated peak withstand current kA 80 100 / 80 100 125 Near fault breaking current kA 90% lk,
75% lk– – – Rated out-of-step breaking current kA 25% lk – – – Creepage distance cm/kV 3.1 2.5, 3.1 – – 1-min power frequency withstand voltage (dry test) – To ground kV 160 275 460 460 – Inter-pole kV 160 275 – – – Fracture kV 160 + 42 275 395 + 145 395 + 145 1-min power frequency withstand voltage (wet test) – To ground kV 160 275 460 460 – Inter-pole kV 160 275 – – – Fracture kV 410 650 / 750 950 + 206 950 + 206 Rated lightning impulse withstand voltage – To ground kV 350 550 / 650 1050 1050 – Inter-pole kV 350 550 / 650 – – 5-min zero-pressure withstand voltage kV 84 95 / 124 189 189 Closing time ms ≤150 ≤150 ≤110 ≤100 Opening time ms ≤30 ≤30 (reclosing ≤35) ≤30 ≤25 Breaking time ms ≤60 ≤60 ≤60 ≤60 Closing-Opening time ms 40-60 40-60 50-70 40-60 Phase asynchronism time ms ≤2 (open), ≤4 (close) ≤2 (open), ≤4 (close) ≤2 (open) ≤2 (open) Rated reclosing sequence – O—0.3s—CO—180s—CO O—0.3s—CO—180s—CO – – SF6 gas rated pressure MPa 0.5 / 0.4 0.5 0.6 0.6 SF6 gas alarm/lock pressure MPa 0.45/0.40, 0.35/0.30 0.45/0.40 0.55/0.50 0.55/0.50 SF6 gas annual leakage rate %/Year ≤0.5 ≤0.5 ≤0.5 ≤0.5 Number of fractures per pole – 1 1 1 1 Mechanical life Times 3000 3000 3000 3000 Terminal mechanical strength – Horizontal longitudinal tension N 790 1250 1500 1500 – Horizontal lateral tension N 750 750 1000 1000 – Vertical tension N 750 1000 1250 1250 Main circuit resistance μΩ ≤50 ≤45 ≤45 ≤42 Matching mechanism – Spring Spring Spring/
HydraulicHydraulic/
PneumaticSF6 gas weight per unit kg 4 6 30 30 Circuit breaker weight kg 1000 1400 3500 4000 / 4500 Standards compliance – GB/T 1984, IEC 60056 GB/T 1984, IEC 60056 GB/T 1984 GB/T 1984
Phone: +8613736779975
E-mail: sales@vcbbreaker.com
Address: 66 Punan Road, Yueqing Economic Development Zone, Zhejiang, China
حق نشر © 2025 Yangmei Electric Group همه حقوق محفوظ است
این وب سایت از کوکی ها استفاده می کند تا اطمینان حاصل شود که بهترین تجربه را در وب سایت ما به دست می آورید.